Working on the customer's Frigidaire. Found a coolant leak, replaced a seal, re-charged, good as new!
Working on the customer's Frigidaire. Found a refrigerant leak, replace a seal, good as new.
"I'm at this customer's home in Pickerington to check out his non-working Carrier furnace.
I completed a scheduled maintenance agreement cooling tune up on a Carrier 13 SEER 3 Ton Air Conditioner I visually inspected the unit checked voltage amps and pressure. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected the evaporator coil. I had to replace the Capacitor that was out of spec. it was Replaced under warranty. I checked refrigerant charge voltage and amps I rinsed the condenser coils with water. cycled and monitored system all operating normally at this time