We were call out to give an estimate to install the electric for the new pool equipment. We will be providing a 60 amp disconnect 4/8 circuits, for the pump and a gfci protected switch for the pool light. Do to the conditions of the old pool light conduit, we need to install a new conduit from the existing junction box next to the pool to the new disconnect location at the side of the house. In order to install the conduit to the light, the concrete will need to be cut (by us). The equipment disconnect will be fed from the existing main panel approximately 20 ft away. The 1 inch conduit will be ran on the surface of the wall along the eve of the house. From the disconnect we will wire the new pool pump and install a conduit to the pool light underground after the concrete is cut. Permit fees are not included in this proposal Thanks for choosing king's electric and air conditioning for your service needs. If you have any questions or concerns please call to speak with your servic