450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for ashland, va


Map of Ashland VA
James M.

James M.


Job Checkin

Upon arrival filter is clean, stat was on. Went outside, breaker was off. Started system up. Blower is clean, evap coil is clean. Condenser coil is clean. All wires are tight. Checked pressures to find txv shutting down showing it has failed. Checked windings on compressor after 3mins of run time and found compressor failing at this time as well. Believe txv failure has been causing stress on the compressor. Called Trane and system is under warranty until next year. Priced up repairs for customer along with a membership. Explained it would take 3-5days for shipping and everything. Customers wife owns the home so they have to talk it over. Showed customer and signed iPad in front of customer.