450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for aylett, va


Map of Aylett VA
James M.

James M.


Job Checkin

Upon arrival started with indoor. Stat was set to cool, went into attic, coil is showing no signs of leaks. Blower is clear, coil is clear. Drain line needs to be cleaned out, small water inside of pan. Wires all tight. System has two drain safety’s. Went outside, system was off due low pressures switch. Found suction valve leaking finished leak searching outdoor unit, found no other leaks. Wires are all tight. System turns over when contacter pushed in. Megohmed compressor and it is green. Called east coast and found system was never registered for warranty. Priced up just repairs, and priced up cleanings and repairs with membership. Customer approved repairs, need to call east coast and order suction valve, customer will pay in full when we return