Upon arrival started with attic system found the blower motor and coil clean no leaks detected on indoor coil. Inspected electrical connections which were clean tight and secured. Drain line flowing properly at this time. When going to the outdoor unit found the coil clean no leaks detected. Electrical connections clean tight and secured system charge was in correct range. Found the bearing for condenser fan failed provided customer with options to adress this. Checking main level indoor found the motor and coil clean no leaks detected on coil at this time. Drain line flowing properly at this time. Found the outdoor unit leaning towards the home provided option to level system to help longevity. Found electrical connection clean secure no damage. Capacitor and condenser fan operating properly at this time. System charge is within manufacturer specifications at this time. Customer declined options at this time to for potential later date.