450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for dumfries, va


Map of Dumfries VA
Hassan D.

Hassan D.


Job Checkin

Cooling inspection Thermostat Inspected thermostat , thermostat is calibrated and operating properly at this time. AHU Inspected high and low voltage wiring, all electrical wiring is intact and tight at this time. Delta T 20F degrees Cleaned evaporator coil and blower wheel/ housing Inspected evaporator coil , coil is clean and free of debris at this time. Return temp 73F , supply temp 91F Return RH 60% , supply RH 66% Return WB 45F , supply WB 25F inspected blower motor, housing and wheel, all is clean and working properly at this time Motor is spinning freely at this time Blower motor amp draw, 0.67amps Inspected cabinet for cleanliness, cabinet is clean at this time. Clear drain line, drain is clean at this time. Inspected air filter, air filter is ok at this time. HP Inspected high and low-voltage wiring, all electrical wiring is intact and tight at this time. Inspected 0FM, motor is spinning freely and operating properly at this time. OFM amp draw , 0.60 amps Inspected