450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for locust grove, va


Map of Locust Grove VA
Josh J.

Josh J.


Job Checkin

Completed inspection on system. Electrical connections are tight. Blower wheel and evap coil are clean. Blower motor and heater packs amping within specs. Cleaned and flushed drain line. Ensuring water safeties functioning properly. Unit is level and draining properly. All ductwork is tight and secure. Reassembled system and proceeded outside. Completed inspection on outdoor unit. Electrical connections are tight. Compressor, cond fan, contractor, cond cap all within specs. Washed cond coil. Pressures are within specs of charging chart. All ops are normal at this time. Customer requested I look over ductwork going into sunroom. Ductwork is intact and insulated. 2 8” supplies go into this room. No return air. Room is completed closed off from rest of house, therefore not able to get proper air turnover. Advised customer that opening the door to the sunroom will increase air turnover. Allowing for better control of temps.