450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for mechanicsville, va


Map of Mechanicsville VA
James M.

James M.


Job Checkin

Upon arrival filters are clean. Spoke with customer and they explained no issues at this time. Went to stat and stat was clean. Went to attic. Heat exchanger checked out good. Coil is clean, no leaks at this time.cleaned flame sensor. Gas pressures where 3.5IWC. Tested safety’s and they are working at this time. Blower has film on it, still recommend to clean. Wires all tight. Blower amped at 1.1amps. Drain line is clear. Spoke to customer about duct work and blower and customer wanted to fix duct work. Re did duct so it was not pinched off. Showed customer pictures and they are happy at this time. System is working well at this time of service.