on arrival customer greeted us at door. Customer said flex line was ripped and leaking. Quoted to replace with insulated r6 flex they went with it. Check furnace blower was a little dirty quoted to clean they went with it. indoor blower amp draws 4.2. This is within manufacture specifications. I then checked the evaporator coil which was clean. Drain line is free of debris at this time and all electrical connections are tight and secure. The system was double filtered with an electronic air cleaner and pleated filters I told the customer to pick one. I’m pretty sure they are going with the pleated filters in the air return grills. And then made my way to the outdoor unit where I started by checking refrigerant pressures they were 122/308 this is within manufacture specifications and then took ampdraws of the outdoor unit the condenser fan was .64 and the compressor was 6.13 A this is within manufacture specifications as well the outdoor coil was dirty and will be cleaned at time of