. Upon arrival spoke with the customer. She said she didn’t have any issues with the system. She showed me the thermostat and filter. Set the thermostat to heat. The filter was a little dirty. Changed filter for the customer. Went to indoor unit. Inspected the evaporator coil. The coil is clean. Leak searched the coil and didn’t find any leaks at this time. Inspected the blower motor and housing. The blower motor amped at 1.29. This is in range. The blower housing is nice and clean. The drain is clear. The condensation pump is working properly. The drain safeties are working properly. Inspected low and high voltage wiring. All wiring is good and tight. All duct work is good and secure. Went to outdoor unit. Cleaned outdoor coil and got all debris out of the bottom of the unit. The Refrigerant pressures were 99/375 in heat and 85/155 in ac. The compressor and condenser fan motor amped within the manufacture specifications. The inverter board is working properly. Inspected low and high v