Completed inspection on attic system. Electrical connections are tight. Blower wheel and evap coil are clean. Blower motor amping within specs. Cleaned and flushed drain line. Ensuring water safeties functioning properly. Unit is level and draining properly. All ductwork is tight and secure. Reassembled system and proceeded outside. Completed inspection on outdoor unit. Electrical connections are tight. Cond fan, contractor, cond cap all within specs. Compressor is drawing higher amperage on startup. Suggest having hard start installed to lower starting amps on compressor. Washed cond coil. Pressures are within specs of charging chart. All ops are normal at this time.