1638 Elkton Road
Elkton, MD 21921
410-392-9350

Job Locations
for bear, de


Map of Bear DE
Clay K.

Clay K.


Job Checkin

Club AC: delta T 17 degree in cooling. Adjusted fan speed for a more adequate static pressure. Heat exchange system good. Indoor and outdoor coils clean. Outdoor RLA rated 19.5 amps actual 9.1 amps. Outdoor FLA rated 1.3 actual 1 amp. Outdoor voltage enhancement system rated 70/5mfd actual 70/5mfd. Treated drains with cleaner.