Performed club ac cleaning refrigerant pumping system factory RLA 21.8amps actual 12.2amps. Air movement system factory specs 1.4amp actual 1.10amps. voltage gateway has a resistance of 14.8ohms contacts are pitted. Voltage enhancement system factory specs 60/5uf actual 56/4.45uf below factory specs. Checked all electrical connections and harness are tight and secured. Condenser coil is clean. Delta T 25. Has some formicary corrosion starting to occur. Inside air movement system has ECM. 20X20X1 filter needs to be replaced checked all electrical wiring connectors and harness are tight and secured at this time. System is operating at end of cleaning .