Performed HSP HVAC maintenance & inspection. Attic unit (80% gas furnace) ducts & filters ok, blower assembly ok, motor FLA 5.2, inducer motor FLA 1.0, gas valve/flame sensor/igniter showing age, ignition sequence ok, condensate drain line clear. Outdoor unit coil dirty, dual capacitor values degraded (33.7/4.4 MFD), wiring ok, bump check ok, static refrigerant pressure 197 (good), outside ambient air temp 62*F. Basement unit (80% gas furnace) ducts & filter ok, blower assembly ok, motor FLA 3.7, inducer motor .8, controls & wiring ok, condensate drain line clear, EZ trap safety switch operational. Outdoor unit coil ok, controls & wiring ok, static refrigerant pressure 185 (ok), bump check ok. Advised customer of discrepancies and provided quote for repairs. Cleaned condenser coil and replaced 35/5 MFD capacitor and cycled unit. Equipment status is good.