MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Job Locations
for louisa, va


Map of Louisa VA
JON B.

JON B.


Job Checkin

NOTE...NOTE... SPOKE WITH PARTS AND A RUNNER WILL HAVE TO TAKE A 20x24x4 MEDIA FILTER TO WENDELLS LAKEHOUSE IN LOUISA. Arrived to find AC not cooling. Upon inspection found failed 45mfd capacitor. Replaced part and tested operation. Pressures 85/146, SH 2.3F, 14F delta T. Spoke with Steve Miller about readings. Did superheat calculation and target SH should be 27F. Recovered 5lbs of R22 one pound at a time until I got my SH reading up to 25F. New pressures 82/136, SH 25F, 10.2F capacity check, 18F delta T, compressor amps 6.85. System hasn't been looked at in a couple of years and refrigerant has never been added to system. System has been overcharged since installation. System back online and operational at this time. Billed to Wendell per the notes.