MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Job Locations
for sterling, va


Map of Sterling VA
LEE D.

LEE D.


Job Checkin

Performed hsphvac maintenance on a 2005 Trane a/c and g/f system. R22. Discussed the refrigerant phaseout. Cust not interested in a system Upgrade at this time. Replaced the cust supplied air filter. Blower recently cleaned. Acoil dirty, ductwork dirty, cond coils are clean. Furnace safeties test ok. 126v. 27 low voltage. 5.3 fla. 49 deg heatrise. The electrical absorption and distribution systems test ok. Installed a new hard start system. After installation of the hard start system the fla ok 11.7. 251v. R22 pressures ok at 64/185 psig. 35A fused service disconnect. Per specs. #8 aluminum service wiring. #10 copper wiring to the outdoor unit. Cust paid in full for the whole home duct cleaning service and the add on dryer vent cleaning. Scheduled 07/01/19 12-2pm. The dryer and dryer vent, along with the ductwork system has plenty of access room. Cust was advised that all registerers must be accessible, any items were to be moved by the cust, and that the 2 return grills had been paint