Sherm S.

Sherm S. Job Checkin

Working on the customer's Frigidaire. Found a coolant leak, replaced a seal, re-charged, good as new!

Working on the customer's Frigidaire. Found a coolant leak, replaced a seal, re-charged, good as new!

Sherm S.

Sherm S. Job Checkin

Working on the customer's Frigidaire. Found a refrigerant leak, replace a seal, good as new.

Working on the customer's Frigidaire. Found a refrigerant leak, replace a seal, good as new.

Sherm S.

Sherm S. Job Checkin

"I'm at this customer's home in Pickerington to check out his non-working Carrier furnace.


"I'm at this customer's home in Pickerington to check out his non-working Carrier furnace.

Adam E.

Adam E. Job Checkin

Upon arrival I replace the Warranty OEM Evaporator Coil. The system is operational upon departure.

Upon arrival I replace the Warranty OEM Evaporator Coil. The system is operational upon departure.

Mike B.

Mike B. Job Checkin

During a tune up on a Comfortmaker air conditioner, I tested the temperatures, pressures and electrical components. The motor surge capacitor was reading out of manufacturers specifications so I replaced. Refrigerant levels are okay and system is cooling properly at time of departure.


Adam N.

Adam N. Job Checkin

During a tune up on a Carrier air conditioner, I tested the temperatures, pressures and electrical components. All tests and readings are within manufacturers specifications at this time and system is cooling at time of departure.

During a tune up on a Carrier air conditioner, I tested the temperatures, pressures and electrical components. All tests and readings are within manufacturers specifications at this time and system is cooling at time of departure.

Adam E.

Adam E. Job Checkin

I completed a spring tune-up tune on a Bryant air conditioner. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.


Adam E.

Adam E. Job Checkin

I replaced a OEM main circuit control board. I verified all wiring to the new board. Cooling upon departure.

I replaced a OEM main circuit control board. I verified all wiring to the new board. Cooling upon departure.

Adam E.

Adam E. Job Checkin

Upon arrival I installed Warranty OEM Evaporator Coil. The system is operational upon departure.


Adam N.

Adam N. Job Checkin

I completed the Spring Tune-Up and Safety Check checklist. The system is operational and running up to manufacture specifications upon departure.


Adam E.

Adam E. Job Checkin

Upon arrival I replaced the condenser fan motor verified wiring by the wiring diagram. The condenser is now operating properly. The system is operational upon departure.

Upon arrival I replaced the condenser fan motor verified wiring by the wiring diagram. The condenser is now operating properly. The system is operational upon departure.

Brett S.

Brett S. Job Checkin

Upon arrival I completed a Half Install of a Carrier 16 SEER 3 Ton Air Conditioner. The system is operational upon departure.

Upon arrival I completed a Half Install of a Carrier 16 SEER 3 Ton Air Conditioner. The system is operational upon departure.

Adam E.

Adam E. Job Checkin

I completed diagnostics and found the issue to a bad transformer. Transformer receiving 120 from the board but not putting out 24v. I replaced transformer and still having the same issue. I found that the white neutral wire was getting 60v. Neutral wire getting charged. Customer had some 12/2 wire and I ran new wire. Verified wiring to the board. I turned the system on and still no 24 to the board. Verified 120 to the furnace. No power to the neutral wire. Verified 120 to the transformer. I verified 24 from the transformer. The board not receiving the 24v. Bad board as well.


Adam N.

Adam N. Job Checkin

I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.


Adam N.

Adam N. Job Checkin

I completed the Spring Tune-Up and Safety Check checklist. The system is operational and running up to manufacture specifications upon departure.

I completed the Spring Tune-Up and Safety Check checklist. The system is operational and running up to manufacture specifications upon departure.