Repaired Bryant Preferred 925S furnace with no heat complaint in Dilworth, MN. Diagnosed failed hot surface igniter using multimeter. Replaced with OEM 201D1-1 igniter. Cleaned flame sensor with emery cloth. Checked inducer motor operation and pressure switch function. Verified proper ignition sequence and flame carryover. Tested limit switches and adjusted blower speed for optimal temperature rise. System restored to full functionality.
Today, I addressed a no-heat issue in a residential HVAC system by performing a detailed clean and service routine. I meticulously cleaned the burner assembly, checked and adjusted the ignition system, and inspected the heat exchanger for cracks or signs of wear. Additionally, I replaced the air filter and tested the system's airflow to ensure efficient and safe operation. This comprehensive service restored heat to the home.
Addressed a warranty-covered leak issue with the pump. Conducted a thorough inspection to pinpoint the source of the leak, identifying a faulty seal. Replaced the defective seal with a new, durable one to rectify the leakage problem. Our meticulous repair ensures the pump operates efficiently and reliably, providing peace of mind to our valued customers.
Attended a "No Heat" service call and determined that the inducer motor was faulty, hindering the furnace's startup process. Swiftly replaced the malfunctioning inducer motor with a new, reliable unit. Thoroughly tested the system to verify proper operation.
We installed an AC there and there is a loud squealing noise coming out of the furnace, check out the noise
HVAC Heating Repair - Busted pipe, left open window, water shutoff to entire building.
Heating Repair - Commercial HVAC not functioning; switching off and on with no consistent heat