12928 Stonecreek Dr Suite B
Pickerington, OH 43147
614-837-4026

Local Reviews
for baltimore, oh

Rated 4.9 out of 5 stars based on 19 customer reviews

Quick to fix

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, great technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Tech was very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Pickerington Heating and Cooling employees are all very professional. I have been a customer for many years and have never had a bad experience. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely, efficient and friendly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job

Good experience,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Sincere concern for my heating problem and knowledgable service rendered.

When a problem arises with my HVAC, I think of no other firm.

  • Overall Experience
  • Quality
  • Price
  • Convenience

the best!

Quick,knowledgeable,courteous,dedicated and professional...just a few words to describe the recent experience with Mike from Pickerington heating and cooling!The office staff were quick to respond when I called and always called back when they said they would.All this during the recent "cold spell"when temps were below zero!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The technicians are always friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The technician was friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for baltimore, oh

Tammy S.

Tammy S. Job Checkin


Anna R.

Anna R. Job Checkin


Aaron B.

Aaron B. Job Checkin

Upon arrival customer stated that the TRANE unit was not turning on, tech found no voltage coming through circuit board, found the low voltage wires that supply power from the transformer to the circuit board were loose, tech re-secured wires, cycled, system is now running, delta t is 75-55 (20 degree drop) system is cooling, OUTDOOR UNIT HAS 245/245 LINE VOLTAGE, 26.2 LOW VOLTAGE, FAN AMP IS 1.1/1.4, COMPRESSOR AMPS 10/18.

Upon arrival customer stated that the TRANE unit was not turning on, tech found no voltage coming through circuit board, found the low voltage wires that supply power from the transformer to the circuit board were loose, tech re-secured wires, cycled, system is now running, delta t is 75-55 (20 degree drop) system is cooling, OUTDOOR UNIT HAS 245/245 LINE VOLTAGE, 26.2 LOW VOLTAGE, FAN AMP IS 1.1/1.4, COMPRESSOR AMPS 10/18.

Scott G.

Scott G. Job Checkin

Performed a diagnostic on a Trane AC. After inspecting, the 240 volt wires were burnt and caused a short. Replaced the wire and confirmed unit is working now.

Performed a diagnostic on a Trane AC. After inspecting, the 240 volt wires were burnt and caused a short. Replaced the wire and confirmed unit is working now.

Scott G.

Scott G. Job Checkin

Tested Freon levels on RHEEM unit. Filled at customer request. Customer requested estimate on new unit.

Tested Freon levels on RHEEM unit.  Filled at customer request. Customer requested estimate on new unit.

Scott G.

Scott G. Job Checkin

Arrived and Found house at 68 degrees. Checked pressures/ coils. Removed outside debris and customer opted to clean themselves.

Arrived and Found house at 68 degrees. Checked pressures/ coils. Removed outside debris and customer opted to clean themselves.

Tammy S.

Tammy S. Job Checkin


Scott G.

Scott G. Job Checkin

During diagnostic visit, Found pressures at 40/180 checked delta t at 14 added freon at customer request new pressures at 70/200 with a SH of 28 unit is operating as expected at this time

During diagnostic visit, Found pressures at 40/180 checked delta t at 14 added freon at customer request new pressures at 70/200 with a SH of 28 unit is operating as expected at this time

Tammy S.

Tammy S. Job Checkin


Scott G.

Scott G. Job Checkin

During A/C vist, found 50/5 capacitor had exploded, replaced at customer request.

During A/C vist, found 50/5 capacitor had exploded, replaced at customer request.

Scott G.

Scott G. Job Checkin

Estimate provided to replace a 2001 Bryant Air Conditioner with a Carrier 16 SEER 5 Ton Air Conditioner. Included a one year service maintenance agreement.

Estimate provided to replace a 2001 Bryant Air Conditioner with a Carrier 16 SEER 5 Ton Air Conditioner. Included a one year service maintenance agreement.

Scott G.

Scott G. Job Checkin

Inspected a Carrier 13 SEER 2.5 Ton Air Conditioner, added R-410A Puron for the system to cool down.

Inspected a Carrier 13 SEER 2.5 Ton Air Conditioner, added R-410A Puron for the system to cool down.

Benjamin J.

Benjamin J. Job Checkin

Checked the evaporator coil and found cased coil shoved in plenum with half coil restricted from airflow. Will return to replace the evaporator coil.

Checked the evaporator coil and found cased coil shoved in plenum with half coil restricted from airflow. Will return to replace the evaporator coil.

Scott G.

Scott G. Job Checkin

Upon inspection found the outside condenser trying to run but the fan not spinning. Unit will kick on by manually moving the fan. Recommended to replace Condenser Fan Motor (Single Speed) with Capacitor & Fan Blades.

Upon inspection found the outside condenser trying to run but the fan not spinning. Unit will kick on by manually moving the fan. Recommended to replace Condenser Fan Motor (Single Speed) with Capacitor & Fan Blades.

Benjamin J.

Benjamin J. Job Checkin

Inspection of malfunctioning Honeywell Pro-Series Thermostat. Found the thermostat installation code set to cooling only. Reset thermostat and system functions properly now.

Inspection of malfunctioning Honeywell Pro-Series Thermostat. Found the thermostat installation code set to cooling only. Reset thermostat and system functions properly now.