12928 Stonecreek Dr Suite B
Pickerington, OH 43147
614-837-4026

Our Top Cities


Local Reviews
for baltimore, oh

Rated 4.9 out of 5 stars based on 19 customer reviews

Quick to fix

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, great technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Tech was very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Pickerington Heating and Cooling employees are all very professional. I have been a customer for many years and have never had a bad experience. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely, efficient and friendly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job

Good experience,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Sincere concern for my heating problem and knowledgable service rendered.

When a problem arises with my HVAC, I think of no other firm.

  • Overall Experience
  • Quality
  • Price
  • Convenience

the best!

Quick,knowledgeable,courteous,dedicated and professional...just a few words to describe the recent experience with Mike from Pickerington heating and cooling!The office staff were quick to respond when I called and always called back when they said they would.All this during the recent "cold spell"when temps were below zero!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The technicians are always friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The technician was friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for baltimore, oh

Greg N.

Greg N. Job Checkin

Diagnostic Service Call for 2019 Carrier Heat Pump and Electric Furnace. Tech found bad wiring.


Greg N.

Greg N. Job Checkin

Diagnostic Service Call for American Standard Furnace.

Diagnostic Service Call for American Standard Furnace.

Christopher M.

Christopher M. Job Checkin

Replace Out of Warranty Part on RHEEM furnace. Replaced circuit board and x13 blower motor.

Replace Out of Warranty Part on RHEEM furnace. Replaced circuit board and x13 blower motor.

Christopher M.

Christopher M. Job Checkin

Replace In Warranty Part for Comfortmaker Gas furnace. Replaced warranty door switch.

Replace In Warranty Part for Comfortmaker Gas furnace. Replaced warranty door switch.

Christopher M.

Christopher M. Job Checkin

Replaced in warranty part on Comfortmaker Gas furnace.

Replaced in warranty part on Comfortmaker Gas furnace.

Christopher M.

Christopher M. Job Checkin

74413


Christopher M.

Christopher M. Job Checkin

Replaced in warranty part on Comfortmaker Gas furnace.

Replaced in warranty part on Comfortmaker Gas furnace.

Aaron B.

Aaron B. Job Checkin

Whole House Duct Cleaning for a 2,400 sq ft house.


Christopher M.

Christopher M. Job Checkin

Furnace Tune Up & Safety Inspection on Comfortmaker Air Handler

Furnace Tune Up & Safety Inspection  on Comfortmaker Air Handler

Bobbie J.

Bobbie J. Job Checkin


Chad S.

Chad S. Job Checkin

2009 Carrier Heating and Cooling System found leaking water due to a clog. Unclogged the system and repaired the trap kit and installed an overflow pipe. System is no longer leaking water.

2009 Carrier Heating and Cooling System found leaking water due to a clog. Unclogged the system and repaired the trap kit and installed an overflow pipe. System is no longer leaking water.

Kendra H.

Kendra H. Job Checkin


Tammy S.

Tammy S. Job Checkin


Anna R.

Anna R. Job Checkin


Aaron B.

Aaron B. Job Checkin

Upon arrival customer stated that the TRANE unit was not turning on, tech found no voltage coming through circuit board, found the low voltage wires that supply power from the transformer to the circuit board were loose, tech re-secured wires, cycled, system is now running, delta t is 75-55 (20 degree drop) system is cooling, OUTDOOR UNIT HAS 245/245 LINE VOLTAGE, 26.2 LOW VOLTAGE, FAN AMP IS 1.1/1.4, COMPRESSOR AMPS 10/18.

Upon arrival customer stated that the TRANE unit was not turning on, tech found no voltage coming through circuit board, found the low voltage wires that supply power from the transformer to the circuit board were loose, tech re-secured wires, cycled, system is now running, delta t is 75-55 (20 degree drop) system is cooling, OUTDOOR UNIT HAS 245/245 LINE VOLTAGE, 26.2 LOW VOLTAGE, FAN AMP IS 1.1/1.4, COMPRESSOR AMPS 10/18.