I found the system not igniting,. I found spark was weak. I cleaned spark rod, now getting spark. I tried to check gas valve pressure unable to open service ports, getting 27 volts to gas valve, based off of this info tech recommended gas valve replacement to correct issue. Customer declined repair at time of appointment and will let us know if they’d like to move forward system not operational upon departure.