316 Primrose Lane
Auburn, GA 30011
(770) 313-8685

Local Reviews
for lawrenceville, ga

Rated 5.0 out of 5 stars based on 2 customer reviews

Chris Boone

Arrived on time. Completed all work as requested. Took care to maintain everything was left clean both inside and outside of house. Answered any question that I had about other items of my concern.


Response from Platinum Comfort Solutions Heating & Cooling:

Thank you Mr. Poirier, we really appreciate the kind words and look forward to providing you you excellent service for many years to come.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Called Platinum out to help with the work on 2 properties. Chris showed up on time and was able to make the fixes I needed for both. Work was great and price was more than fair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lawrenceville, ga

Chris B.

Chris B. Job Checkin

Installed this New Goodman 2.5 air conditioner, matching evaporator coil and variable speed natural gas furnace. 10 year all parts warranty, 1 year labor, 2 year outdoor unit replacement if compressor fails, Lifetime on the heat exchanger.

Installed this New Goodman 2.5 air conditioner, matching evaporator coil and variable speed natural gas furnace. 10 year all parts warranty, 1 year labor, 2 year outdoor unit replacement if compressor fails, Lifetime on the heat exchanger.

Chris B.

Chris B. Job Checkin

Replacing this 25 plus year old York air conditioner. Compressor is going out and system has several Freon leaks. New HVAC system will be Goodman and it will have 10 year all parts, 1 year labor, lifetime heat exchanger warranty and 2 year outdoor unit replacement if compressor fails.

Replacing this 25 plus year old York air conditioner. Compressor is going out and system has several Freon leaks. New HVAC system will be Goodman and it will have 10 year all parts, 1 year labor, lifetime heat exchanger warranty and 2 year outdoor unit replacement if compressor fails.

Chris B.

Chris B. Job Checkin

Sealing up air leaks on this home that being sold next week. Also tidying up systems and making them look better. Another company installed these systems last year.

Sealing up air leaks on this home that being sold next week. Also tidying up systems and making them look better. Another company installed these systems last year.

Chris B.

Chris B. Job Checkin

Found this 15 year old Goodman air conditioner not coming on due to a bad capacitor. The outdoor fan would still run but the compressor would not. Outdoor coils were also very dirty. Cleaned outdoor coils with chemical and it has dropped the head pressure by 50 psi.

Found this 15 year old Goodman air conditioner not coming on due to a bad capacitor. The outdoor fan would still run but the compressor would not. Outdoor coils were also very dirty. Cleaned outdoor coils with chemical and it has dropped the head pressure by 50 psi.

Chris B.

Chris B. Job Checkin

Found this 19 year old Armstrong air conditioner not cooling due to loose wires at the thermostat and at the outdoor unit. Also cleaned outdoor coils and added Freon to get system back cooling.

Found this 19 year old Armstrong air conditioner not cooling due to loose wires at the thermostat and at the outdoor unit. Also cleaned outdoor coils and added Freon to get system back cooling.

Chris B.

Chris B. Job Checkin

Installed this new 15 seer 2.5 ton heat pump that qualifies for a $400 rebate from Jackson EMC. This system also has zone control on it as well. New system has a 10 year all parts warranty, 2 year outdoor unit replacement if compressor fails and 1 year labor warranty.

Installed this new 15 seer 2.5 ton heat pump that qualifies for a $400 rebate from Jackson EMC. This system also has zone control on it as well. New system has a 10 year all parts warranty, 2 year outdoor unit replacement if compressor fails and 1 year labor warranty.

Chris B.

Chris B. Job Checkin

Found not enough power coming to house from the Jackson EMC power meter. This is causing the air conditioner not to work and half the lights in the house.

Found not enough power coming to house from the Jackson EMC power meter. This is causing the air conditioner not to work and half the lights in the house.

Chris B.

Chris B. Job Checkin

Performed cooling maintenance on the air conditioning side of this 5 year old Carrier heat pump system. Cleaned washable filter. Chemical cleaned outdoor coils. Checked Freon readings and pressures. Flushed condensation drain line. Checked temperature differences through indoor air handler. Tested electrical components and compressor. Recommended replacing capacitor due to age and it reading weak.

Performed cooling maintenance on the air conditioning side of this 5 year old Carrier heat pump system. Cleaned washable filter. Chemical cleaned outdoor coils. Checked Freon readings and pressures. Flushed condensation drain line. Checked temperature differences through indoor air handler. Tested electrical components and compressor. Recommended replacing capacitor due to age and it reading weak.

Chris B.

Chris B. Job Checkin

Performing cooling maintenance on this 5 year old Lennox air conditioner. Chemical cleaned outdoor coils. Checked Freon readings and pressures. Added cleaner to condensation drain line. Tested electrical components and compressor. Added surge protector to outdoor condenser unit.

Performing cooling maintenance on this 5 year old Lennox air conditioner. Chemical cleaned outdoor coils. Checked Freon readings and pressures. Added cleaner to condensation drain line. Tested electrical components and compressor. Added surge protector to outdoor condenser unit.

Chris B.

Chris B. Job Checkin

This drain line was not draining properly and filling the indoor secondary drain pan full of water. Repaired cracked drain line and retested. This is a 6 year old Nortek air conditioner.

This drain line was not draining properly and filling the indoor secondary drain pan full of water. Repaired cracked drain line and retested. This is a 6 year old Nortek air conditioner.

Chris B.

Chris B. Job Checkin

Replaced leaking evaporator coil on this 6 year old Air Ease air conditioner. Also replaced condensation pump and dual capacitor. Chemically cleaned outdoor coils as well. New coil has a 10 years parts warranty.

Replaced leaking evaporator coil on this 6 year old Air Ease air conditioner. Also replaced condensation pump and dual capacitor. Chemically cleaned outdoor coils as well. New coil has a 10 years parts warranty.

Chris B.

Chris B. Job Checkin

Replacing thermostats and fuses on this home that a customer is refinishing. Unfortunately some kids broke in and smashed the whole house up and caused $100,000 in damages.

Replacing thermostats and fuses on this home that a customer is refinishing. Unfortunately some kids broke in and smashed the whole house up and caused $100,000 in damages.

Chris B.

Chris B. Job Checkin

Replumbed gas meter back to house because gas company refused to do it even though they are supposed to. Tested operations of new furnaces.

Replumbed gas meter back to house because gas company refused to do it even though they are supposed to. Tested operations of new furnaces.