Have any feedback for us? We'd love to hear it! Call us at (864) 310-7704 and let us know how we are doing.
Installation of Lennox XC16 16 SEER air conditioning system completed for residence in Piedmont. The new 3-ton variable-speed system replaces an aging 10 SEER unit that experienced compressor failure. Installation included complete replacement of indoor evaporator coil, refrigerant lines, and condensate drain system. Modified existing ductwork at air handler connection to reduce static pressure and improve overall system efficiency. Performed manual J load calculation prior to installation to verify proper sizing. System includes Lennox iComfort S30 smart thermostat for enhanced temperature control and system monitoring. Vacuum tested system to 350 microns to ensure complete removal of moisture and non-condensables. Charged system according to manufacturer superheat/subcooling specifications. Final testing indicates all parameters within optimal ranges with 19.2°F temperature differential. System is operating at 16.2 SEER under current conditions, exceeding rated efficiency. Provided c