22311 Diesel Dr.
McCalla, AL 35111
(205) 966-9463

Our Top Cities


Job Locations
for birmingham, al


Map of Birmingham AL
Brandon B.

Brandon B.


Job Checkin

Addressed a malfunctioning Goodman GSX140361 air conditioning unit. Diagnosed faulty dual capacitor using Fluke 902 FC HVAC clamp meter. Replaced with TITAN PRO TOCF45 45/5 MFD 370/440V capacitor. Cleaned condenser coils using Nu-Calgon 4291-08 Nu-Brite to improve heat transfer efficiency. Recharged system with R-410A refrigerant, utilizing Fieldpiece SM480V digital manifold. Installed new Honeywell R8285D5001 control center for enhanced system management. Conducted amperage draw test on compressor and fan motors. Post-repair performance check confirmed proper cooling operation and restored system efficiency, ensuring optimal comfort for the homeowner.