He found and fixed problem
Response from R.S. Andrews Services:
Lynne, we are so glad that your HVAC repair service met your expectations! Thanks for the great review!
They’ve always come out right away when we called - even nights and weekends, for emergency calls. Friendly staff. Reliable.
Completed an AC repair on a Carrier Infinity 24ANB7 unit. Diagnosed a malfunctioning capacitor and replaced it with a Carrier OEM part to restore proper function. Checked refrigerant levels and topped off with R-410A to ensure optimal cooling. Cleaned the evaporator and condenser coils for better efficiency and airflow. Inspected and secured all electrical connections to prevent future issues. Regular maintenance and timely repairs extend the lifespan of your AC system. For expert HVAC services, contact us for reliable solutions.
Repaired a Bradford White 40-gallon water heater that was not heating properly. Diagnosed the issue as a faulty thermocouple and replaced it with a Bradford White OEM part to ensure reliable operation. Flushed the tank to remove sediment buildup, which can affect heating efficiency. Checked the thermostat settings and tested the unit to confirm it was heating water effectively. Regular maintenance and prompt repairs are essential for optimal performance. For expert water heater repair services, contact us.
Performed maintenance on a Rinnai RL75 tankless water heater to ensure optimal performance. Descaled the heat exchanger using a vinegar solution to remove mineral buildup, which can affect efficiency. Inspected the venting system and gas lines for any leaks or obstructions, and cleaned the water filter to ensure proper water flow. Checked the temperature settings and tested the unit to confirm it was heating water efficiently. Regular maintenance is essential for extending the life of your tankless water heater. For expert service, contact us.
Performed a repair on a Trane XR13 AC unit due to faulty electrical connections. Identified and replaced damaged wiring and connectors with new high-quality electrical components to ensure reliable performance. Inspected the contactor and capacitor, replacing them with OEM Trane parts to prevent future issues. Tested the system to confirm all electrical connections were secure and the unit was operating efficiently. Proper electrical maintenance is crucial for HVAC longevity. For expert AC repairs, contact us to keep your system running smoothly.
Completed a repair on a Goodman GSX16 AC unit. Diagnosed a malfunctioning compressor and replaced it with a Goodman OEM part. Checked and recharged refrigerant levels with R-410A to ensure optimal cooling performance. Inspected and cleaned the condenser coils and ensured all electrical connections were secure. Verified that the thermostat was functioning correctly. Regular maintenance and prompt repairs are essential for extending the life of your AC unit. For expert HVAC repair services, contact us to keep your system running efficiently.
Installed a Zoeller M53 Mighty-Mate sump pump in a residential basement. Connected the discharge line with a check valve to prevent backflow and ensure efficient operation. Ensured the pit was clean and properly sized for the unit. Wired the pump to a dedicated GFCI outlet for safety and tested it by simulating water entry to confirm it activated and discharged correctly. Proper sump pump installation prevents basement flooding. For expert plumbing services, contact us to safeguard your home.
Repaired an AC unit with frozen coils, a common issue in Lennox XC16 models. Diagnosed the problem as low refrigerant levels and a dirty air filter. Replaced the filter and recharged the system with R-410A refrigerant to restore proper cooling function. Inspected the evaporator coil for ice buildup and ensured the airflow was unobstructed. Regular maintenance and prompt repairs are essential for efficient operation. For expert HVAC services, contact us to keep your system running smoothly.
Installed Rinnai RU199iN tankless water heater in Pooler, GA residence. Mounted unit on exterior wall, connected gas line and water pipes. Installed new venting system using PVC pipe. Configured temperature settings and tested flow rates. Verified proper ignition and consistent hot water delivery. Conducted final safety checks and demonstrated operation to homeowner.
Repaired a Goodman GSX160601 air conditioner, installed in 2018. Located a low refrigerant charge and identified a leak in the liquid line using a Fieldpiece SRL8 heated diode leak detector. Repaired the leak with a SwageLok fitting, pulled a vacuum with a Robinair VacuMaster, and recharged with Mexichem R-410A per manufacturer specifications. Replaced the contactor and run capacitor from Diversitech. The system now operates at proper temperature split and energy efficiency ratings.
Restoring optimal cooling performance was the objective of this recent AC repair call. Upon inspection, the issue stemmed from a failed contactor which prevented the condensing unit from running. I replaced the dated 24V contactor with a new dual pole unit rated for this system's specifications. To protect the compressor, I installed a hard start kit compatible with the equipment's capacitor values. All low voltage control wiring terminations were tightened and checked for any potential shorts or grounding issues. After enabling power, I monitored refrigerant pressures, validated the charge, and confirmed the unit was maintaining the manufacturer's recommended superheat and subcooling levels.
Today's air conditioning repair service call involved replacing a failed blower motor. First, I disconnected power to the indoor unit and removed the access panels. Using a multimeter, I confirmed the existing motor had failed by checking for an open winding. I then removed the blower wheel assembly and installed a new factory original equipment motor, ensuring proper alignment and airflow clearances. All electrical connections were securely terminated. After reassembly, I verified proper operation by monitoring amperage draw, airflow, and temperature differential across the evaporator coil. The system is now circulating conditioned air effectively throughout the home.
During the AC repair service call, I conducted thorough diagnostics to identify the root cause of the system failure. Upon inspection, the run capacitor tested defective, causing the compressor to overheat and trip the high-pressure switch. I replaced the dual-rated capacitor and pulled a deep vacuum to remove moisture. After recharging with the correct refrigerant volume, the system was restored to normal operating parameters, ensuring reliable cooling performance.
Upon completing the AC maintenance service call, I performed a comprehensive 26-point inspection. The condenser coil was thoroughly brushed and rinsed to remove built-up dirt and cottonwood. Refrigerant levels tested low at 68 psig, so I evacuated the system and recharged with 3.2 lbs of R-410A refrigerant per manufacturer specifications. TheContractorBlue pleated filter was replaced, and the evaporator coil was foamed to restore heat transfer efficiency. All electrical terminations were tightened, and voltage was verified within tolerances.
"Executed comprehensive air duct cleaning: Employed a HEPA-filtered vacuum and brush system to eliminate contaminants from duct interiors. Inspected ducts with a borescope for hidden debris and mold. Applied an EPA-certified antimicrobial treatment to disinfect duct surfaces. Verified airflow using an anemometer, ensuring balanced distribution. Completed the job with a final system inspection to enhance overall air quality and HVAC efficiency." --- Performed thorough air duct cleaning in Savannah this morning. Utilized a negative air machine and rotary brushes to dislodge and extract accumulated dust and allergens. Inspected ductwork with a digital camera for blockages and microbial growth, applying a sanitizing agent where necessary. Conducted airflow analysis post-cleaning to confirm restored efficiency and uniform air distribution. Final inspection ensured the system's optimal performance and indoor air quality improvement.
I responded to a service call for an underperforming Carrier Infinity 19VS air conditioning unit. The homeowner stated the upstairs rooms were not cooling adequately. Upon inspection, I found the indoor evaporator coil was severely blocked with dirt and debris. I utilized a Nu-Calgon CoilShine coil cleaner and CoilShine flush 'n rinse solution to fully clean the coil. Afterwards, the system's airflow and cooling capacity were restored to normal levels. The Carrier Infinity 19VS is operating efficiently again, providing the expected comfort. Preventative maintenance like routine coil cleaning is crucial for optimal performance.