This morning, I fixed an air conditioning unit that was not cooling adequately. I diagnosed the issue as a faulty capacitor, confirmed with a Fluke 117 multimeter, and replaced it with a Titan Pro 45/5 MFD dual run capacitor. Additionally, I cleaned the condenser coils using Nu-Calgon coil cleaner. After reassembly, I tested the unit to ensure efficient cooling and proper operation.