Plumbing Inspection Report Service Performed: Complimentary Plumbing Inspection Location: Crawlspace Date: [Insert Date] Findings: 1. Drain Line Issue: A belly was identified in the drain line servicing the laundry sink, which may impede proper drainage and lead to future blockages. 2. Copper Line Concerns: Copper piping routed through the foam insulation was found to have sections wrapped with galvanized sheet tape without appropriate panel tape or protective separation at the pipe hangers. This improper protection method poses a risk of pipe abrasion and potential leaks. 3. ABS Line Condition: Similar deficiencies were noted with the 2-inch ABS (Acrylonitrile Butadiene Styrene) piping, lacking proper support and protection at hanger points. 4. Substandard Connections: Multiple shard-by (improper or makeshift) connections were observed throughout the plumbing system. These are not compliant with recommended residential plumbing standards and could lead to system failu