5712 Highland Rd
Santa Fe, TX 77517
346-326-2665

Job Locations
for rosharon, tx


Map of Rosharon TX
Alex T.

Alex T.


Job Checkin

Ac repair: primary drain line was clogged, sending water into supply plenum, and causing a drip onto the ceiling in master bedroom. There are also PDC joints on secondary drain line that are unglued. Blower wheel is very dirty, has approximately half inch dirt build up. Recommend clearing primary drain line, and repairing sections of PVC, and cleaning blower wheel and also signing up for Comfort Club membership to help with preventative maintenance in future. Primary drain line is clear, drained one full gallon of water through drain line without issue. Repaired secondary drain line and perform heating maintenance. System is achieving 28 degree temperature rise.