4401 Eastern Ave #17
Baltimore, MD 21224
410 781-1002

Job Locations
for woodlawn, md


Map of Woodlawn MD
Yonas M.

Yonas M.


Job Checkin

VOLTAGE ABSORPTION SYSTEM REPAIR ALSO ADD HARD START KIT TO AVOID FUTURE PROBLEMS Service call 09/24/19 on arrival set unit to call for cooling measured supply and return air temp no DT checked electrical connections checked voltage and amps checked air filter checked condenser drain line checked outdoor condenser unit checked voltage absorption system is fell below spec so I suggested replacing now to outdoor unit to operating also I suggested the additional of the hard start kit to ease all electrical strain on the compressor and other electrical device in the outdoor unit.plus it lowers energy consumption I wired in with new dual run capacitor l tested start up and unit began operating very smoothly without any hesitating checked electrical connections checked voltage and amps measured pressure and temp and they are ideal indicating zero leaks measured superheat and subcooling unit operating normal at this time. Collected $621.70 on C.C on file