Indoor unit Blower amps are in range Run cap is borderline weak and should be replaced to prevent failure Reading 9.6 and the minimum is 9.5. / 10 Cabinet contains biological growth and should be addressed with preventative measures. The air handler is trapped outside and does not have a primary safety switch . This could cause flooding in the event of a drain line back up Outdoor unit Coils are clean, amps are in range Pressures are in range Run cap is below weak and should be changed today. Reading 25/4.9 supposed to be 45/5 Replaced the run cap under warranty Once the system has started and is operating, the run capacitor takes over and provides the extra power to run the air conditioner for long periods of time. When the air conditioner is running, both capacitors create and store energy for the push for the next cycle.