4751 Oceanside Blvd Suite E
Oceanside, CA 92056
760-842-7630

Local Reviews
for rancho santa fe, ca

Rated 5.0 out of 5 stars based on 6 customer reviews

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service and knowledge

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Ty is always great at what he does

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service.

The technician was smart, courteous, knowledgeable and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service. Great People.

Super quick response to a no water situation. Thorough and considerate.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rancho santa fe, ca

Christopher  M.

Christopher M. Job Checkin

AC Maintenance completed on two 8 yr split gas Maytag systems; new 16 x 25 x 1 and 14 x 25 x 1 fiber filters in place; cleared both condensation drain lines; cleaned both condenser coils; ran both units to cool; all components operating properly within manufacturer specifications; no recommendations at this time.


Ken S.

Ken S. Job Checkin

Replaced indoor evaporator coil under warranty. Adjusted charge on outdoor unit with 410 a refrigerant.


Christopher  M.

Christopher M. Job Checkin

AC Maintenance completed on two 3 ton split gas closet/ garage York and Maytag units; 16 x 25 x 4 & 16 x 25 x 1 filters in place in good condition; cleaned condenser coils and cleared both condensation drain lines; ran both units to cool; all components operating properly within manufacturer specifications, no recommendations at this time


Ty J.

Ty J. Job Checkin

Checked refrigerant pressure on the 3.5 ton condensing unit, noticed they were low and proceeded with a leak search and found an evaporator coil leak.


Ramon E.

Ramon E. Job Checkin

Thompson removed hot and cold cartridges in downstairs powder room faucet. Hand cleaned debris from inside cartridge. Put back cartridges. Flushed out water. Faucet works fine for now. Checked all the reset of the faucets and showers in the house. Howard stated that the toilets continue to run in the master and down stairs powder room even with the new kholer flappers. He is going to shut the valves off at night and see if the water level drops in the morning. Spoke directly with homeowner Work under warranty No charge for warranty work Pictures and videos attached


Ignacio V.

Ignacio V. Job Checkin

Thompson plumbing replaced two kholer flappers in master bathroom and down stairs powder room. Replaced garbage disposal and repaired pop up assembly in apartment room. Thompson also replaced 30’ of corroded 1” copper pipe above pantry attic. Thompson used ridged copper and press fittings. Turned water back on flushed out system checked for leaks. No leaks found cleaned up work area and took pictures. 90 day warranty on flappers and garbage disposal 1 year warranty on new copper pipe No warranty on original pop up assembly


Ignacio V.

Ignacio V. Job Checkin

Customer approved estimate over the phone.


Ramon E.

Ramon E. Job Checkin

Thompson Plumber presented estimate to replace section of corroded copper pipe above pantry and replace one horsepower garbage disposal and pop-up assembly in guest house.


Ty J.

Ty J. Job Checkin

System inspection for 8 units. Main issue was to confirm static pressure readings on the systems. All systems have high static pressures on both supply and return sides except the family room.


Christopher  M.

Christopher M. Job Checkin

AC Maintenance completed on 3 yr split gas Trane/AC Pro 5 ton attic unit; electronic air cleaners in place is good condition; clear drain line; cleaned condenser coil; all components operating properly within manufacturer specifications; no recommendations at this time.


Christopher  M.

Christopher M. Job Checkin

Heating and Cooling Maintenance completed on 9 yr split gas 5 ton Rheem attic system, 9 yr split gas 3 ton Rheem attic system, (2) 9 yr 4 ton split gas Rheem attic systems; replaced (2) 16 x 25 x 1 filters, (1) 20 x 25 x 1 filter, and (1) 14 x 25 x 1 filter; filters in place were heavily restricted; cleared all 4 condensation drain lines; cleaned all 4 condenser coils; all 4 condenser coils were restricted; recommend installing 4 Hard Start kits in all Rheem condensers; schematics call for “Start Relay & Start Capacitor” as optional components; Installation of Hard Start Kits will increase life expectancy and efficiency of units and delay replacement; also recommend installing 4 surge protectors to protect outdoor units from damage resulting from power surges.


Ken S.

Ken S. Job Checkin

Installed new 9K 18 seer mini split . Electrical was done by others.


Ignacio V.

Ignacio V. Job Checkin

Price is for the installation of a new automatic water shut off valve. The valve will be place at the main water line before it enters the home. We will need to re do the plumbing in order to make the new shut off valve fit into the system. Once installed we will set up the unit for the customer. Price is for all parts and labor.


Ty J.

Ty J. Job Checkin

Cooling maintenance on three systems. 11 yr old lennox, 12 yr old Rheem and a 26 yr old carrier. Carrier unit is sloping drastically and should be level, rheem unit is operating within specs and the lennox has a slight restriction and further investigation is needed.


Christopher  M.

Christopher M. Job Checkin

Performed 3 AC Maintenance on 3 split Lennox split gas units; 3 electronic air clean cleaners clean; 3 condenser coil cleanings; 2, 3, and 5 ton units 7 years old; 2 ton unit showing low refrigerant; cleared condensation drain lines, recommend 3 energy assist kits and surge protection to protect, increase efficiency, and extend life of all 14 SEER units. Call to schedule.