Client called us out today due to AC not properly cooling down home. Another technician had been out one month prior and found pressures to be extremely low and pumped up system and injected UV dye/sealant. System is only producing a 6 to 7° split. Hooked up refrigerant gauges and found pressures to be low again. This would indicate a major leak somewhere on the system. Explained to client what steps would need to be taken to find the leak without UV being present. Due to the state and age of the system, and what would be required for repairs, advised client look at system replacement. Client has agreed to bronze package AC only change out. Given authorization from management to credit $700 from last months repair towards new system. Client is scheduled for August 2nd. Thank you for trusting Thompson with your heating, cooling and plumbing needs.