Jason did a very good job. We got a thorough inspection at a fair price. He gave us a full report when he was finished. Appreciate the good service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jason was courteous efficient and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was great

Very thorough

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

good

good job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very professional and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very pleasant and professional service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chandler, az

Keith H.

Keith H. Job Checkin

replaceing condenser fan motor on a rooftop package heat pump commercial


Chris R.

Chris R. Job Checkin

PROBLEM 37 PT INSPECTION TRANE DIAGNOSIS ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME UNIT IS COOLING WITH A 20 PLUS DEGREE TEMPERATURE SPLIT ACROSS THE COIL 10 MFD RUN CAPACITOR IS WEAK THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTOR /RECOMMEND REPLACING THE CAP REPLACED 10 MFD RUN CAPACITOR UNDER WARRANTY TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN


Stuart M.

Stuart M. Job Checkin

PERFORMED PMP INSPECTION ON TWO SPLIT GAS AC UNITS CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RANGE VERIFIED TEMP SPLIT ACROSS COILS CLEANED OUTDOOR COILS TIGHTENED ELECTRICAL CONNECTIONS CHECKED IN RUSH AMPS OF COMPRESSORS INSPECTED CONDITION OF UNITS UNITS RUNNING IN COOLING AT TIME OF INSPECTION. DOWNSTAIRS UNIT HAS WEAK 5 MF RUN CAPACITOR. CAPACITOR WAS REPLACED AT TIME OF INSPECTION. WHILE RUNNING MOTOR WITH WEAK CAPACITOR MAY HAVE CAUSED PERMANENT INTERNAL DAMAGE. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.


Stuart M.

Stuart M. Job Checkin

PROBLEM: UNIT NOT COOLING DIAGNOSIS: OFM MOTOR SUFFERED PERMANENT INTERNAL DAMAGE PREVIOUSLY DUE TO FAILED CAPACITOR. OFM NOT FUNCTIONING AT TIME OF INSPECTION AND DUE TO AGE NEW UNIT RECOMMENDED TO BE INSTALLED. SENT CUSTOMER ESTIMATE FOR NEW UNIT WAITING APPROVAL.


Chris R.

Chris R. Job Checkin

PROBLEM NO COOL A/H CARRIER FA4BNFC60000AAAA 3604A73739 R-22 CONDENSER PAYNE PH13NR06000GAKAA 1314X74415 DIAGNOSIS FAILED BLOWER MOTOR /BLOWER WHEEL IS DAMAGED COIL IS VERY RUSTED/FOUND A LEAK AT THE EQUILIZER TUB CONNECTION ON THE SUCTION LINE DUE TO THE OVERALL CONDITION OF THE UNIT WE RECOMMEND REPLACING THE UNIT DRAIN PAN IS FULL OF DEBRIS AND RUST COMPRESSOR MAY HAVE TAKEN INTERNAL DAMAGE SYSTEM IS R-22


Keith H.

Keith H. Job Checkin

Weak 35\5 dual capacitor. TESTED both units in cooling. TESTED FREON LEVELS amp draws and run capcitors. Repair. Replaced 35/5 dual run cap under warranty


Chris R.

Chris R. Job Checkin

PROBLEM 37 PT INSPECTION @2 NO COOL ON DOWNSTAIRS UNIT UPSTAIRS /DAY AND NIGHT PHR53000KTP0A1 C172932806 40/5 DUAL RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED AT NEXT VISIT ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE COIL NO OTHER ISSUES AT THIS TIME DISCOUNT 69.99 IF CUSTOMER BUYS A NEW UNIT


Chris R.

Chris R. Job Checkin

TRANE TTR060C100A2 L434SWDBF DIAGNOSIS UNIT IS SHOWING HEAVY WEAR DUE TO AGE AND USAGE RUSTED EVAPORATOR COIL COIL POSSIBLE DIRTY / WE WOULD NEED FURTHER DIAGNOSTICS TO PROPERLY DETERMINE RUSTED SECONDARY DRAIN PAN WEAK 5MFD AND 10 MFD RUN CAPACITORS /THIS WILL ALLOW INTERNAL DAMAGE TO THE MOTORS CHARGE LOOKS LOW AT THIS TIME /WE WOULD NEED TO VERIFY CONDITION OF THE EVAPORATOR COIL TO PROPERLY CHARGE THE UNIT WE DUE NOT RECOMMENDED ANY COSTLY REPAIRS ON THIS UNIT CUSTOMER DECLINED ANY REPAIRS AT THIS TIME


Keith H.

Keith H. Job Checkin

PROBLEM: NO COOL/ NO INDOOR FAN RUNNING. DIAGNOSIS: UPON ARRIVAL THE SYSTEM WAS TURNED OFF. I TURNED THE SYSTEM ON AND FOUND UNIT TO FUCTION CORRECTLY. INDOOR AND OUTDOOR FANS TURN ON. COMPRESSOR TURNED ON AND THE SYSTEM BEGAN TO COOL. PERFORMED A MAINTENANCE ON THE ROOF TOP PACKAGE UNIT. OVERALL CONDITION IS SYSTEM SHOWNING NORMAL WEAR DUE TO AGE. TIGHTEN ELECTRICAL CONNECTIONS. HOSED OFF THE OUTDOOR COIL. TESTED FREON LEVELS. TESTED MOTOR AMP DRAWS AND CAPACITORS. CONDENSER FAN MOTOR SHOWING WEAR. LEAKING BEARINGS. MOTOR MAY HAVE ISSUES WHEN THE SUMMER TEMPS RISE. NOTE: IF THE INDOOR FAN FAILS TO RUN AGAIN. WEATHER MASTERS RECOMMENDS LEAVING SYSTEM RUNNING CALL IMMEDIATLY SO WE CAN SEE THE ISSUE AS IT A OCCURES. MODEL 4WCZ6036A1000AA SERAL 8084WLJ9H


Chris R.

Chris R. Job Checkin

REPLACE 1/8HP BLOWER MOTOR AND WHEEL WE WILL NEED TO ORDER PARTS/5 TO 7 BUSINESS DAY FOR ARRIVAL 5/2/19 MADE RECOMMENDED REPAIRS /UNIT IS COOLING AT THIS TIME


Keith H.

Keith H. Job Checkin

PROVIDE ESTIMATE FOR WIRELESS SENSORS.


Stuart M.

Stuart M. Job Checkin

Weather Masters successfully completed a 37 point inspection - weather Masters tightened all electrical fittings - checked all Freon levels and pressures - checked amperage of indoor and outdoor motor. Working at intended anprage -Ensured run capacitor is running with proper MFD's and is not leaking - subcool is 10 -examined indoor and outdoor coil. Outdoor coil was cleaned with water -temperature split is normal at 18 -thermostat is working as should -filter is changed regularly and is currently clean -customer says unit is working well At this time, the system is running normally.


Stuart M.

Stuart M. Job Checkin

PROBLEM: INDOOR FAN NOT TURNING ON. DIAGNOSIS: BLOWER MOTORS BEARINGS HAVE GONE OUT SND BLOWER WHEEL IS NOW BENT RECOMMEND REPAIRS: REPLACE BLOWER MOTOR AND WHEEL WITH OEM PARTS. INCLUDES CAPACITOR


Chris R.

Chris R. Job Checkin

PROBLEM WO/16784 37PT INSPECTION @2 UPSTAIRS /DAY AND NIGHT N4A530GKC101 E161100098 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR /THIS IS WITHIN MANUFACTURE SPECIFICATIONS THE 40/5 DUAL RUN CAPACITOR IS SHOWING WEAR BUT STILL WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME /MAY NEED TO BE REPLACED AT NEXT VISIT CONDENSER FAN MOTOR IS LEAKING OIL AND MAY FAIL PREMATURELY BECAUSE OF THE HIGH AMBIENT TEMPERATURES ALL MOTOR AMPS ARE WITHIN MANUFACTURE SPECIFICATIONS AT THIS TIME NO RECOMMENDED REPAIRS AT THIS TIME TIGHTENED ALL ELECTRICAL CONNECTIONS HOSED OFF OUTDOOR COIL FLUSHED DRAIN DOWNSTAIRS CA5536VKD1 L961676501 DIAGNOSIS VERIFIED SEQUENCE OF OPERATION IN THE COOLING MODE AND THE UNIT IS COOLING AT WITH A 20 DEGREE SPLIT ACROSS THE EVAPORATOR COIL DIRTY BLOWER WHEEL AND MOTOR /POSSIBLE DIRTY EVAPORATOR COIL /DO TO AGE AND CONDITION COSTLY REPAIRS ARE NOT RECOMMENDED THE 7.5 MFD RUN CAP


Robert T.

Robert T. Job Checkin

REPLACE EVAPORATOR COIL UNDER WARRANTY 15LBS 410 REFRIGERANT /NO WARRANTY REFRIGERANT REPLACE CONDENSER FAN MOTOR AND DUAL RUN CAPACITOR UNDER WARRANTY REPLACE VARIABLE SPEED BLOWER MOTOR UNDER WARRANTY