235 S. Mountainland Dr.
Orem, UT 84058
8012248899

Job Locations
for cedar hills, ut


Map of Cedar Hills UT
Jeff M.

Jeff M.


Job Checkin

AC tune up refer to health report card. Electrically system is performing very well no high amp draws at this point in time. Indoor system is clean with no restriction in airflow. Both indoor and outdoor units do not have a surge protection device in use given the indoor and outdoor equipment are intelligent appliances with control board highly recommend systems to have surge protection. Indoor unit does not have a wet switch in use can help prevent water damage to equipment given close proximity to plumbing and main drain for unit. Outdoor unit does not have a hard start kit this aids in keeping initial amp draws in the compressor to be at a minimum keeping the compressor motor windings healthier for longer. Outdoor unit was dirty and it was cleaned off will want to keep an eye on cleanliness of condensing coil just due to the amount of debris that was cleaned out of it. Overall system performing well. Recommendations refer to estimates. Installed surge protectors on both outsid