CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal. CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal. No leaks upon completion. Condenser fan motor replacement was recommended