Great service

Serviceman was knowledgeable and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Service

Steve came out quickly and diagnosed the problem with our fridge. He found the part that we needed and gave us a quote and then came back to tell us he’d found it cheaper and would pass on the savings to us. He came back the next day to fix it and everything is working awesome! He was friendly and affordable and even fixed a few things that he noticed were amiss and didn’t charge us extra. Awesome experience!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Knew just what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Freezer Repair

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service !!!

David was prompt and quickly determined the problem with my 16 year old stove. A new part was ordered and he returned to install it. Highly recommend Affordable Appliance Repair !!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Carlos was very friendly and explained the details of servicing our dryer we will definitely request him again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports dryer is not heating CAUSE: Found dryer high limit thermostat open circuit CORRECTION: reset high limit thermostat . Unit is heating fine. CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Nick H.

Nick H. Job Checkin

CONCERN Customer reports refrigerator was leaking aware CAUSE: Found water filter behind fridge was leaking water, disconnected water line CORRECTION: Re-connected to original water supply source and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports microwave lights not working. CAUSE: Control board failure. . CORRECTION: Installed new control board, and tested. Operation now normal.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports washer is not spinning; no agitate. CAUSE: Found washer motor to transmission coupler failure; Agitate gears failure. CORRECTION: Replaced coupler & agitate gears, and tested. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected refrigerator thermostat cold control operation, found refrigerator cold control failed. CORRECTION: Replaced refrigerator cold control and tested. Operation now normal. Also replaced 6 bulbs with LED bulbs.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal.


Michael H.

Michael H. Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports cooktop burners are not working properly CAUSE: Found gas flow orifices partially clogged. CORRECTION: R&R burner plates to clean and tested, operation now normal.