18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews

Rated 4.9 out of 5 stars based on 299 customer reviews

Awesome service

Very quick and works perfectly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Corrected Thermador oven temperature!

David is an excellent electrician and repair Man. He always does a great job. He is a keeper!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, great communication and timely service.....thank you Josh!

Excellent experience..... no more issues with my ice maker! Thank you Josh!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service ever!

Completely satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fixing the washer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very friendly

Very prompt and amazing service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service

This is the 2nd time I used your service. I always think I am going to have to buy a new fridge then I call you And you fix it like new Again. Very happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, with a flexible schedule.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

The icemaker still is not working right and I tried to call you back and got hung up on three to four times it makes ice and doesn't stop and the cube ice doesn't come out.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Daren O.

Daren O. Job Checkin

CONCERN: Customer reports BOSCH dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Josh  L.

Josh L. Job Checkin

CONCERN: Customer reports JENN AIR refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice and debris, operation now normal.


Josh  L.

Josh L. Job Checkin

CONCERN: LG Washer is not draining or spinning Model WM2650HRA DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports LG Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports ice maker is not making much ice. DIAGNOSTIC AND CAUSE: Found a sprayer nozzle clogged with debris. CORRECTION: Removed debris and tested. Operation now normal


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports SUB ZERO refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


Josh  L.

Josh L. Job Checkin

CONCERN: Customer reports SAMSUNG Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to adaptive defrost. Cause of failure found ADC main control board shorted at the output line voltage to the adaptive defrost system. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports exhaust fan is not coming up. CAUSE: Found control board failed. CORRECTION: Replaced and tested. Also retaped ductwork.


David R.

David R. Job Checkin

CONCERN: Customer reports SUB ZERO freezer is building frost and ice. DIAGNOSTIC AND CAUSE: Inspected compressor operation, evaporator fan and condenser fan operation, all normal. Found frost build up on evaporator coils. Tested defrost heater and thermostat for continuity, normal. Found drain trough heater shorted. CORRECTION: Defrosted extreme amount of ice and frost from evaporator. Replaced drain trough heater.. Tested operation, all normal upon completion.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports FRIGIDIARE dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports KITCHEN AID refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected refrigerator for proper voltage supply, voltage is normal at the time of inspection. Inspected for proper voltage from terminal block to control, voltage is normal at the time of inspection. Inspected voltage from control to DC inverter, found voltage supply to the inverter normal however no voltage coming out of the inverter to the compressor. Found compressor inverter control board failed. CORRECTION: Replaced compressor inverter control board and tested. Operation now normal.


Josh  L.

Josh L. Job Checkin

CONCERN: FRIGIDAIRE Washer is not draining or spinning MODEL FAFW3801LW5 DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports that the LG washer is not draining. "OE" error code. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested, Operation now normal.


David R.

David R. Job Checkin

CONCERN Customer reports VIKING refrigerator is beeping and freezer is not quite cold enough. CAUSE: Found evaporator fan motor unplugged. CORRECTION: Plugged back in and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports ice maker is not working properly. CAUSE: Found ice maker drain pump failed. Also found ice maker circulation pump failed. Also found cutting grid wire corroded and came apart when handling. CORRECTION: Replaced ice maker drain pump and hose, replaced circulation pump, repaired cutting grid wire, and tested unit. Operation now normal.