Job Checkin

CONCERN: Customer reports refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected refrigerator for proper voltage supply, voltage is normal at the time of inspection. Inspected for proper voltage from terminal block to control, voltage is normal at the time of inspection. Inspected voltage from control to DC inverter, found voltage supply to the inverter normal however no voltage coming out of the inverter to the compressor. Found compressor inverter control board failed. CORRECTION: Replaced compressor inverter control board and tested. Operation now normal. CONCERN: Customer reports refrigerator. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.