CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal. CONCERN: Customer reports water leaking into the refrigerator section of the refrigerator. CAUSE: Found defrost drain clogged with debris. CORRECTION: Removed debris and installed defrost drain heater. And new drain tube kit Tested operation, all normal upon completion. No leaks upon completion.