CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Tested for voltage from adaptive defrost control board to defrost components. No voltage from the main control board to the defrost. Cause of failure found ADC main control board shorted at the output line voltage to the defrost components. CORRECTION: Replaced ADC main control board and tested. Operation now normal.