2806 SW 34th Ter.
Cape Coral, FL 3914
239-673-8247

Our Top Cities


Local Reviews
for naples, fl

Rated 5.0 out of 5 stars based on 12 customer reviews

Great service

The electrician was very responsive to my questions and needs. What was unfortunate, is that my American Home Warranty didn’t really cover what was wrong.


Response from Federal Electric Inc:

Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, prompt and save me lots of $$.


Response from Federal Electric Inc:

Thank you for the wonderful review and for taking the time to share your feedback.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super helpful!

Vinny was awesome! We went over the process and he got right to work. He took the time to explain what he did, how everything works and the steps we’ll take to ensure a successful experience. Knowledgeable, efficient and courteous— couldn’t ask for anything more!


Response from Federal Electric Inc:

Your kind words about our electrical service mean a lot to us. Thanks for leaving such a positive review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent electrician, very responsive

Responded quickly, provided excellent service on big issues and small, at a reasonable price. Will definitely call him again.


Response from Federal Electric Inc:

Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Efficient,,excellent communicator, problem solver, on time (even early).

See above


Response from Federal Electric Inc:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great


Response from Federal Electric Inc:

We are pleased to know your experience with us was a good one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Quick installation


Response from Federal Electric Inc:

We thank you for sharing your positive experience. It made our day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable/helpful.


Response from Federal Electric Inc:

Thank you so much for taking the time to leave us this amazing review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

N/A


Response from Federal Electric Inc:

We are so glad to hear that you had a good experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service

Ur serviceman Vinny was so very helpful, he was just wonderful service tech. U should be thankful he represents ur company.


Response from Federal Electric Inc:

Thank you for sharing your kind words with us. It means the world to us and to our entire team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

GFCI installation

Great job


Response from Federal Electric Inc:

Your kind words about our electrician service mean a lot to us. Thanks for leaving such a positive review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service-professional and courteous service technician.

Vinny did a great job replacing my ceiling fan. I highly reccomend Vinny and Federal Electric but stay away from American Home Shield. AHS is a terrible company to do business with.


Response from Federal Electric Inc:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for naples, fl

Vinicius L.

Vinicius L. Job Checkin

I installed a new Hunter ceiling fan in a client’s living room. After ensuring the ceiling box was properly braced, I assembled the fan and mounted it securely. I wired the fan to a Lutron Maestro fan control switch for easy speed and light control. Once installation was complete, I tested the fan’s operation at all speeds and confirmed that the light kit was functioning correctly, providing both air circulation and lighting.


Vinicius L.

Vinicius L. Job Checkin

I conducted commercial electrical repairs in a building experiencing intermittent power outages. Using a Klein Tools circuit tracer, I traced the issue to a failing circuit breaker in the main panel. I replaced the faulty Square D breaker with a new one and performed a load test to ensure the system could handle the building’s electrical demands. The repair resolved the power issues, and the office is now operating smoothly.


Vinicius L.

Vinicius L. Job Checkin

Completed rewiring of downstairs bathroom and kitchen today. Installed new 12/2 and 14/2 Romex cables for circuits. Replaced outdated receptacles with Leviton GFCI outlets in wet areas. Installed dedicated 20A circuit for kitchen appliances using Square D QO120 breaker. Updated lighting with Lutron Caseta smart switches. Used Klein Tools wire strippers and Ideal wire connectors for terminations. Mounted new plastic junction boxes. Tested all circuits with Fluke 117 multimeter for proper voltage and grounding. Labeled panel clearly. Job completed in 9 hours, bringing wiring up to current code standards.


Vinicius L.

Vinicius L. Job Checkin

Repaired a Generac Guardian 22kW whole home generator today. Diagnosed faulty voltage regulator using Fluke 87V multimeter. Replaced with new Generac 0G8442A111 AVR. Changed oil using Mobil 1 5W-30 synthetic and installed new Generac 070185E oil filter. Replaced spark plugs with NGK BPR6ES. Cleaned carburetor using CRC carb cleaner. Adjusted governor spring tension. Tested battery with Midtronics capacitance tester. Performed load bank test using ASCO 1340 portable load bank. Verified proper voltage output and frequency. Updated firmware using GenLink software. Completed repair in 4 hours, restoring reliable backup power.


Vinicius L.

Vinicius L. Job Checkin

Performed complete electrical rewire of a home to current NEC standards. Removed outdated knob-and-tube wiring and fuse panel. Installed new 200-amp main service panel with copper feeder wires in rigid conduit. Ran new branch circuits using NM-B cable protected by AFCI/GFCI breakers. Replaced all receptacles, switches and light fixtures. Grounded system to two 8-foot ground rods per 250.53(A)(2). Passed final inspection.


Vinicius L.

Vinicius L. Job Checkin

Installed new electrical outlets. Shut off power at the circuit breaker for safety. Ran new wiring from the main panel to the installation points. Installed outlet boxes and secured wiring connections. Mounted and wired the new outlets, ensuring proper grounding and polarity. Tested each outlet for voltage and correct operation. Restored power and confirmed functionality. Client reviewed and approved the installation.


Vinicius L.

Vinicius L. Job Checkin

Recently finished installing new lighting fixtures and recessed lighting in a home in Naples, FL. Installed stylish LED pendant lights and recessed lighting from Kichler. The upgrade enhances ambiance and energy efficiency, providing the homeowner with modern, well-lit spaces while reducing electricity costs and maintenance needs.


Vinicius L.

Vinicius L. Job Checkin

Installed multiple ceiling fans in Naples, FL, enhancing air circulation. Each Hunter model fan was strategically installed in various rooms for optimal airflow and comfort. This upgrade ensures improved ventilation and energy efficiency throughout the home, promoting a more comfortable living environment.


Vinicius L.

Vinicius L. Job Checkin

Installed a whole-home surge protector in Naples, FL, enhancing electrical safety. The Leviton 51120-1 model was professionally installed to safeguard all circuits from power surges. This addition protects electronic devices and appliances, ensuring peace of mind and minimizing potential damage from electrical spikes.


Vinicius L.

Vinicius L. Job Checkin

Successfully repaired a Maytag front-loading washer in Naples, FL, addressing drainage issues. Diagnosed and resolved the problem by inspecting the drain pump and removing debris causing the blockage. Checked for any additional issues, ensuring the washer now drains efficiently. The client can now enjoy a fully functional appliance.


Vinicius L.

Vinicius L. Job Checkin

Just finalized a whole-home surge protection installation in Naples, FL, offering extensive protection for electrical devices. The client wisely opted for this safeguard against sudden power surges, protecting valuable electronics and appliances from potential damage. With the increased reliability of their electrical system, the customer gains peace of mind, ensuring a secure and resilient home environment.


Vinicius L.

Vinicius L. Job Checkin

Addressed a dryer malfunction in Naples, FL, finding a faulty heating element that hindered proper drying. Efficiently replaced the damaged heating element, ensuring will have full use of their dryer again. Additionally, conducted a comprehensive inspection to check for potential issues and guarantee overall performance.


Vinicius L.

Vinicius L. Job Checkin

Arrived at a customer's home to repair their electrical panel. I inspected the panel and found a faulty circuit breaker was the cause of the problem. I meticulously installed a new circuit breaker, ensuring the electrical connections were secure upon completion. The electrical panel is functioning properly again for the thankful homeowner.


Vinicius L.

Vinicius L. Job Checkin

Went out to install whole-house surge protection in a residential home. I first assessed the home's electrical system to provide the right surge protection devices. I then carefully installed the system in the home. The surge protection will keep the home's electronics and appliances safe and secure. The customer was pleased with the service.


Vinicius L.

Vinicius L. Job Checkin

Provided an appliance repair at a customer's home. They had called us because their fridge was not cooling inside properly. Upon arrival, I inspected the fridge and found that the fan motor had gone bad. The old faulty motor was removed and replaced with a new one. The refrigerator is now operating correctly and the new motor is more reliable for the fridge's cooling needs.