On time and plan to use them again.
Response from Federal Electric Inc:
Thank you for the 5-star review, we are happy to provide you excellent electrical repair & service!
Response from Federal Electric Inc:
We count ourselves lucky for customers like you and look forward to working with you again in the future!
Response from Federal Electric Inc:
We’re so happy you loved your experience and can’t wait to have you back for your next service appointment.
Response from Federal Electric Inc:
Thank you for sharing your kind words with us. It means the world to us and to our entire team!
Response from Federal Electric Inc:
We are pleased to know your experience with us was a good one!
Couldn't ask for better service.
Response from Federal Electric Inc:
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Response from Federal Electric Inc:
Thanks for sharing your review with us and the community.
Response from Federal Electric Inc:
We are pleased to know your experience with us was a good one!
I called for a fan replacement on a Monday and they came within an hour. Fair price, quick service, and he did a great job.
Response from Federal Electric Inc:
Your kind words about our electrician service mean a lot to us. Thanks for leaving such a positive review!
He was great. You have a mew customer
Response from Federal Electric Inc:
We're thrilled to hear that our electrician service exceeded your expectations. Thanks for the kind words!
During a troubleshooting job, the homeowner reported intermittent power loss. I inspected the circuit breakers and checked all outlet wiring for loose connections. Using a multimeter, I identified a faulty GFCI outlet causing the issue. I replaced the GFCI and rechecked the system. After confirming the circuits were stable and the outlets functioning correctly, I explained how to monitor for potential future issues. The home’s electrical system is now working reliably.
I performed a panel box upgrade for a home with an outdated 100-amp service. I installed a new Siemens 200-amp load center, providing increased capacity for the home’s growing electrical needs. After transferring circuits to the new panel, I ensured all connections were secure and properly grounded. I also installed a main breaker for added protection. Following the upgrade, I tested the entire system to verify that it was functioning efficiently and safely.
I upgraded several standard electrical outlets to Legrand USB charging outlets in a client’s home. After shutting off the power, I removed the old outlets and installed the new units, which provide both standard 120V and USB charging ports. I carefully wired each outlet, ensuring proper polarity and grounding. After installation, I tested each outlet with a USB tester to confirm they were delivering the correct voltage and current for device charging.
Repaired a Generac Guardian 22kW whole home generator today. Diagnosed faulty voltage regulator using Fluke 87V multimeter. Replaced with new Generac 0G8442A111 AVR. Changed oil using Mobil 1 5W-30 synthetic and installed new Generac 070185E oil filter. Replaced spark plugs with NGK BPR6ES. Cleaned carburetor using CRC carb cleaner. Adjusted governor spring tension. Tested battery with Midtronics capacitance tester. Performed load bank test using ASCO 1340 portable load bank. Verified proper voltage output and frequency. Updated firmware using GenLink software. Completed repair in 4 hours, restoring reliable backup power.
Completed a residential panel upgrade today. Replaced old 100A panel with Square D Homeline 200A, 40-space main breaker panel. Installed new 2/0 AWG copper service entrance cable. Upgraded grounding system with 6 AWG copper to new ground rods. Transferred and labeled all existing circuits. Added AFCI and GFCI breakers as required by code. Used Greenlee knockout set for new conduit entries. Secured panel with Tapcon concrete anchors. Torqued all connections with Klein Tools digital torque wrench. Performed voltage drop and continuity tests with Fluke multimeter. Coordinated with utility for meter swap. Completed upgrade in 10 hours, significantly improving home's electrical capacity and safety.
Installed recessed lighting in three rooms today. Used Halo H7ICAT 6-inch housings with Lithonia 3000K LED retrofit modules. Cut holes with Milwaukee hole saw. Wired fixtures using 14/2 Romex cable. Installed Lutron Caseta dimmer switches for each room. Used Klein Tools wire strippers and Ideal wire connectors. Secured housings with mounting clips. Tested circuit with Fluke multimeter. Completed installation of 18 fixtures across living room, kitchen, and master bedroom in 8 hours.
Diagnosed and repaired dishwasher electrical issue. Found faulty wiring connection causing intermittent power loss. Replaced damaged wiring and secured all electrical connections. Tested the control panel and verified proper operation of all cycles. Ensured grounding and circuit integrity. Dishwasher is now functioning correctly and meets electrical safety standards. Client reviewed and approved the repair.
Installed Hubbell USB-charging electrical outlet rated 3.6A per NFPA 70 code. Cut opening in existing receptacle box, secured new device using machine screws. Ran 14/2 NM-B cable from nearest junction box, connected hot/neutral/ground per manufacturer wiring diagram using approved wire nuts. GFCI protected USB ports for safe charging.
Completed an electrical panel upgrade today, replacing an outdated 100-amp panel with a robust 200-amp model to accommodate increased household demand. Ensured all circuit breakers were properly labeled and installed according to current electrical codes. Also upgraded grounding and bonding to enhance safety and system reliability, ensuring all connections were secure and compliant.
I conducted maintenance on a Generac Guardian Series home generator, model 7043. This comprehensive service included changing the oil with Generac Full Synthetic Motor Oil, replacing the spark plugs, and installing a new air filter, model 0J8478S. I also tested the battery and ensured the firmware was up to date for optimal performance. The system was then run through a diagnostic test to ensure reliability.
I installed an Eaton CHSPT2ULTRA Ultimate Surge Protection 3rd Edition, providing comprehensive electrical surge protection for the entire house. The installation involved integrating the device directly into the home’s main electrical panel, ensuring all circuits were safeguarded against voltage spikes. I then conducted a series of tests to verify the system's functionality, ensuring reliable protection for all connected appliances and electronics.
I repaired a Samsung DV42H5000EW electric dryer, replacing the faulty heating element (model DC47-00019A) to restore functionality. Additionally, I installed a Lutron Caseta Wireless Smart Lighting Dimmer Switch in the living room, integrating it with the home's existing electrical system for adjustable lighting. The process included wiring the switch, programming it for user convenience, and testing to ensure optimal operation.
Just completed installing new LED lighting at a business in Ft. Myers, FL. Installed energy-efficient Philips LED bulbs. They offer bright, long-lasting illumination, reducing energy costs and maintenance for the customer. Improved lighting enhances visibility and creates a more inviting atmosphere for everyone.
Completed multiple ceiling fan installations in Fort Myers, FL, enhancing the interior decor for a client. Encountered minor wiring challenges but efficiently resolved them to ensure seamless operation. The new ceiling fans provide both aesthetic appeal and functional cooling, contributing to the refreshed ambiance of the home.
For a great customer in Fort Myers, FL, rewired a dishwasher, ensuring seamless operation. Identified and repaired faulty wiring connections to enhance efficiency. The dishwasher is now operating smoothly, providing reliable service for our satisfied client. Another successful electrical service ensuring optimal performance for essential home appliances.