According to the time frame when work was done. Permit was never pulled. Electrical panel was built over which vialoates code of clearance of 3ft. Also nuetrals and grounds are double tapped under screws inside panel. And arc faults are not installed where required. In hallway of downstairs there needs to be a three way switch operating the landing light. Also there should be lights in all the bedroom closets. There is no disconnect on water heater. There needs to be additional smoke detection installed upstairs and downstairs that meet code requirements. One regular in each bedroom. One carbon on each level of home. All have to be hardwired with battery back up. All outlets in downstairs are not tamper resistant. Panel needs to be brought out flush with wall and secured.