85 Franklin Rd
Dover, NJ 07801
973-366-8754

Job Locations
for south orange, nj


Map of South Orange NJ
Devon B.

Devon B.


Job Checkin

Winterization Upon trying to winterize system, water turn off in utility room is broken, valve can be rotated in full 360°, there is no start or stop point. Also controller is reading zero station error. Will need to troubleshoot controller may possibly need to be replaced, valve, locator to determine if wire is spliced at some point, or if valves are faulty. Request having two people and about 4 to 6 hours to repair and winterize after. We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identi