When we got here 1 & 2 didn’t work so we saw that the connections were bad so re did them and they did turn on properly. Then when we checked the rest of the system we saw nothing had pressure the heads would not pop up at all so we looked at the DCA and it didn’t have handles and we also saw 1 head in zone 1 and 1 head in zone 2 said he wanted us to fix the 2 leaking heads to see if that helped we changed them but they didn’t really get more pressure so we told the customer it sounds like the DCA isn’t open properly and there is no way to open it more since it had no handles but we were explaining to him there’s no guarantee that’s the issue and if it’s not that then maybe the valves aren’t opening up correctly. He said he wanted to do the DCA so we replaced it and saw that it picked up all the heads but it still didn’t have the proper pressure that it’s supposed to. So we recommended to split up a few zones in the front. We also found a leak in zone 6 when everything got more pressur