Job Checkin

During the system check, the concern that the client had about the water bill being high is most likely a combination of the leaking sprayheads, and potentially the controller having electrical issues and running longer or more often than expected. The controllers about 30 years old, and it is recommended to have it replaced. A total of 19 pop-up spray heads were flagged to be replaced due to the spray heads, either leaking significantly at the base of the stem and body, or not retracting after the zone was shut off. A total of five pop-up sprayheads were flagged to be capped as they are no longer needed for where the heads are positioned. A total of four nozzles on existing spray heads were flagged to be replaced as the heads themselves were in good working order, but the nozzles were damaged or were not the correct shape and size for the placement of the heads. The issues listed above were presented to the client, and approval was given to cap the five pop-up sprayheads that are no