During the system check, the clients concern about zone two not turning on was found and resolved. When checking the zone wires at the controller, zones two and three registered at over 100 ohms. The valves for zones two and three were flagged to be replaced as they had failed electrically, and did not Operate correctly when tested. The vast majority of the pop-up spray heads throughout the property were either leaking significantly at the base of the stem and body, or did not retract after the zone was shut off. A total of 37 pop-up sprayheads were flagged to be replaced out of the 45 sprayheads on the property. The Issues listed above were presented to the client, and approval was given to replace the valves for zones two and three. An estimate with the remaining recommended repairs will be sent to the client with an invoice for the work that was completed during today’s visit.