446 Windsor Park Dr
Dayton, OH 45459
937-238-8620

Job Locations
for carlisle, oh


Map of Carlisle OH
Matthew O.

Matthew O.


Job Checkin

Customer has requested diagnostics for well system. Well system is operating on a 30/50 psi switch. Remove and install new pressure gauge on well system. After installing new pressure gauge, we ran water at both hose bibs and utility sink. Creating a call for large demand of water. Pump was able to handle demand, and satisfy switch in seconds. This is a sign of a very healthy and efficient pump. Ohms test. Thus will determine wether our electrical current is having any resistance traveling through motor/windings. We would like to see resistance at 3 ohms or less. Ohms reading is at 2.2. Very healthy. Amps test. We want to test amps to check efficiency, and to make sure our motor is not working too hard to operate. We would like to see amp draw no higher than 6. Amps reading tops out at 1. Motor seems to be fully operational, and efficient.