CUSTOMER STATED : Floor is wet from leak in wall coming from laundry area. TECHNICIAN NOTES : Out to the residence for the concerns of there being a leak within the wall in the laundry area of the home. Home is vacant. After removing drywall around existing washing machine box, we found the the leak is due to a leaking 1/2 inch CPVC 90 and the FIP connection to the cold side of the washing machine box valve. While on site I have also found a malfunctioning pressure regulating valve. Water pressure read at 50 from water heater but dropped 10 pounds when turning on kitchen faucet. Homes NTE is $350. RESOLUTION : Replaced cold side valve for the existing washing machine box and made necessary pipe modifications to the CPVC 1/2 piping. After making repairs, home has been fully pressurized and repairs ,are today are showing no further concerns at this point in time. JOB NOTES : Need to bill bridge homes for repairs made today. Clean out located on left side of front door. Ple