CUSTOMER STATED: Water pressure is low TECHNICIAN NOTES: Out today for the tenants concerns of there being low water pressure and for a leak under the kitchen sink. Tenant not on site while out today Homes water pressure testing below 20 PSI from both hose bibs. 25AUB prv is located in the garage. Dishwasher drain hose is leaking at the tubular connection under kitchen sink. RESOLUTION/RECOMMENDATIONS: Replaced 25 AUB prv with a double union watts for easier change out. Tightened drain hose for dishwasher that connected to the tubular piping under the kitchen sink. Homes water pressure is 60 PSI with new prv. Dishwasher has been drained prior to tightening connection and there are no further leaks at this point in time. JOB NOTES: Home on septic system. Please bill resipro for work completed today. JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) Job complete PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE