Job Checkin

Replace Pressure Switch on Submersible Well Pump Tank, Replace Gauge on Tank Tee -Charge Tank to 28 psi, Ensure Pressure Switch Operates Between 30-50 psi, Check Amperage on Pump. -Includes 10% SPP Discount If Further Changes are Needed, Upfront Pricing Will be Given. After arriving to the home, the homeowner made me aware of how his submersible Well pump quit working last night. He has a back up jet pump he used for the mean time, but he is unsure of what was needed to get done. The home was built in the late 19th century/early 20th century. The submersible pump and drilled well was installed in 2001. The homeowner replaced the pressure tank in October of 2022. I was not able to reprime the pressure switch, so I gave him a price to diagnose the issue and to replace the pressure switch. After gaining approval, I replaced the pressure switch, Nipple, and pressure gauge. I also ensured the pressure tank was charged to 28psi. Once the new switch was installed, we tested the system and I