Pump Up to 1000 Gallons in Main Septic Tank -Replacement of Pump in Basin, Install Zoeller 1/2 HP Manual Effluent Pump -Install New Outdoor Control Box, with New Floats to Include On, Off, and Alarm Function. Run Floats on Float Tree, Independent from Discharge Line. Install Conduit Sealer on Line Entering Tank and Leaving Control Box. -Replace Check Valve, Union and Shutoff on Discharge Line While Replacing Pump. -Includes Service Partner Plan: Annual Safety Checks on Whole House Plumbing, Includes Annual Water Heater Flush, No Dispatch Fees, 10% SPP Discount, Up to 3 Years Parts and Labor Warranty if SPP is Current I arrived today to take a look at a septic alarm issue. The homeowner had their alarm go off last night around 10 pm. They were able to get it to shutoff, but the alarm came back on this morning. I began by removing the access lids off of three risers. 2 for the main tank, and 1 for the effluent pump basin. The homeowners just moved here within the past 2 years. Chatham C